1
0
Fork 0
mirror of https://github.com/munin-monitoring/contrib.git synced 2025-07-21 18:41:03 +00:00

Fix trivial instances of wrong autoconf exitcodes

This commit is contained in:
Lars Kruse 2018-09-16 04:01:57 +02:00
parent 99f6979f22
commit e4cd049b01
152 changed files with 225 additions and 344 deletions

View file

@ -19,11 +19,10 @@ my $mbmon = "/usr/local/bin/mbmon";
if ($ARGV[0] eq 'autoconf') {
if (-x $mbmon) {
print "yes\n";
exit 0;
} else {
print "no\n";
exit 1;
}
exit 0;
} elsif ($ARGV[0] eq 'config') {
print <<EOF;
graph_title CPU temperature

View file

@ -30,11 +30,10 @@ fi
if [ "$1" = "autoconf" ]; then
if [ $NVCLOCK_OK -eq 1 ]; then
echo yes
exit 0
else
echo no
exit 1
fi
exit 0
fi
if [ "$1" = "config" ]; then