mirror of
https://github.com/munin-monitoring/contrib.git
synced 2025-07-21 18:41:03 +00:00
Add arcconf plugin
Plugin monitors raid adapters, logical devices and physical devices managed by arcconf
This commit is contained in:
parent
e3f08308ab
commit
80e9b6dd98
1 changed files with 255 additions and 0 deletions
255
plugins/disk/arcconf_
Executable file
255
plugins/disk/arcconf_
Executable file
|
@ -0,0 +1,255 @@
|
||||||
|
#!/bin/sh
|
||||||
|
|
||||||
|
set -e
|
||||||
|
|
||||||
|
: << =cut
|
||||||
|
|
||||||
|
=head1 NAME
|
||||||
|
|
||||||
|
arcconf - Monitor RAID adapters, logical devices and physical disks with arcconf
|
||||||
|
|
||||||
|
=head1 APPLICABLE SYSTEMS
|
||||||
|
|
||||||
|
Raid adapters managed with arcconf
|
||||||
|
|
||||||
|
=head1 CONFIGURATION
|
||||||
|
|
||||||
|
With "arcconf list" you find available controllers. Link arcconf_ with
|
||||||
|
specified controller id.
|
||||||
|
|
||||||
|
ln -s /usr/share/munin/plugins/arcconf_ /etc/munin/plugins/arcconf_1
|
||||||
|
|
||||||
|
arcconf_bin - Path to arcconf binary
|
||||||
|
|
||||||
|
[arcconf_*]
|
||||||
|
user root
|
||||||
|
env.arcconf_bin /usr/local/sbin/arcconf
|
||||||
|
|
||||||
|
[arcconf_1]
|
||||||
|
env.min_online_disks 12 # Miniaml online disks
|
||||||
|
env.max_adapter_temp 50 # Adapter temperature threshold
|
||||||
|
|
||||||
|
=head1 AUTHOR
|
||||||
|
|
||||||
|
Copyright (C) 2020 Sebastian L. (https://momou.ch)
|
||||||
|
|
||||||
|
=head1 LICENSE
|
||||||
|
|
||||||
|
GPLv2
|
||||||
|
|
||||||
|
=head1 MAGIC MARKERS
|
||||||
|
|
||||||
|
#%# family=auto
|
||||||
|
#%# capabilities=autoconf
|
||||||
|
|
||||||
|
=cut
|
||||||
|
|
||||||
|
. "$MUNIN_LIBDIR/plugins/plugin.sh"
|
||||||
|
|
||||||
|
if [ "${MUNIN_DEBUG:-0}" = 1 ]; then
|
||||||
|
set -x
|
||||||
|
fi
|
||||||
|
|
||||||
|
arcconf_bin="${arcconf_bin:-/usr/local/sbin/arcconf}"
|
||||||
|
adapter_id="${0##*arcconf_}"
|
||||||
|
|
||||||
|
ARCCONF=$($arcconf_bin getconfig "$adapter_id")
|
||||||
|
ARCCONF_DISKS=$(echo "$ARCCONF" | grep -Pzo 'Device\ #(.|\n)*Service Hours.*[0-9]{1,6}' | tr '\0' '\n')
|
||||||
|
ARCCONF_LOGICALDISKS=$(echo "$ARCCONF" | grep -Pzo 'Logical Device number (.|\n)*Parity Initialization Status' | tr '\0' '\n')
|
||||||
|
ARCCONF_SMARTSTATS=$($arcconf_bin getsmartstats "$adapter_id")
|
||||||
|
|
||||||
|
logicaldisks=$(echo "$ARCCONF_LOGICALDISKS" | grep -oE 'Logical Device number [0-9]+' | sed 's/Logical Device number //g')
|
||||||
|
disks=$(echo "$ARCCONF_DISKS" | grep -oE 'Device #[0-9]+' | sed 's/Device #//g')
|
||||||
|
|
||||||
|
case $1 in
|
||||||
|
|
||||||
|
autoconf)
|
||||||
|
if [ -x "$arcconf_bin" ]; then
|
||||||
|
if [ -z "$(command -v arcconf)" ]; then
|
||||||
|
echo "no (arcconf not found)"
|
||||||
|
exit 0
|
||||||
|
else
|
||||||
|
echo "yes"
|
||||||
|
exit 0
|
||||||
|
fi
|
||||||
|
else
|
||||||
|
echo "no (/usr/local/sbin/arcconf not found)"
|
||||||
|
exit 0
|
||||||
|
fi
|
||||||
|
;;
|
||||||
|
|
||||||
|
config)
|
||||||
|
adaptername=$(echo "$ARCCONF" | grep "Controller Model" | cut -d ":" -f 2 | xargs)
|
||||||
|
|
||||||
|
echo "multigraph arcconf_${adapter_id}_logicaldisks"
|
||||||
|
echo "graph_title arcconf_${adapter_id} - Status of logical disks"
|
||||||
|
echo "graph_info arcconf_${adapter_id} - Status of logical disks on $adaptername adapter"
|
||||||
|
echo "graph_args -u 1 -l 0"
|
||||||
|
echo "graph_category disk"
|
||||||
|
echo "graph_vlabel Online status"
|
||||||
|
for logicaldisk in $logicaldisks; do
|
||||||
|
raid_level=$(echo "$ARCCONF_LOGICALDISKS" | grep 'RAID level' | cut -d ":" -f 2 | xargs)
|
||||||
|
echo "status_logicaldisk_$logicaldisk.label Logical disk $logicaldisk (raid $raid_level) status is optimal"
|
||||||
|
echo "status_logicaldisk_$logicaldisk.info Status of logical disk $logicaldisk (raid $raid_level) is optimal"
|
||||||
|
echo "status_logicaldisk_$logicaldisk.min 0"
|
||||||
|
echo "status_logicaldisk_$logicaldisk.warning 1:"
|
||||||
|
done
|
||||||
|
|
||||||
|
echo "multigraph arcconf_${adapter_id}_online_disks"
|
||||||
|
echo "graph_title arcconf_${adapter_id} - Online disks"
|
||||||
|
echo "graph_info arcconf_${adapter_id} - Online disks on $adaptername adapter"
|
||||||
|
echo "graph_args -A -l 0"
|
||||||
|
echo "graph_category disk"
|
||||||
|
echo "graph_vlabel Number of disks"
|
||||||
|
echo "online_disks.label Online disks"
|
||||||
|
echo "online_disks.info Current number of online disks on $adaptername adapter"
|
||||||
|
echo "online_disks.min 0"
|
||||||
|
if [ -n "${min_online_disks}" ]; then
|
||||||
|
echo "online_disks.warning $min_online_disks:"
|
||||||
|
fi
|
||||||
|
|
||||||
|
echo "multigraph arcconf_${adapter_id}_temp"
|
||||||
|
echo "graph_title arcconf_${adapter_id} - Temperature of adapter"
|
||||||
|
echo "graph_info arcconf_${adapter_id} - Temperature of $adaptername adapter"
|
||||||
|
echo "graph_args -Y -A -l 0"
|
||||||
|
echo "graph_category disk"
|
||||||
|
echo "graph_vlabel C"
|
||||||
|
echo "adapter_temp.label Adapter temperature"
|
||||||
|
echo "adapter_temp.info Current $adaptername adapter temperature"
|
||||||
|
echo "adapter_temp.min 0"
|
||||||
|
if [ -n "${max_adapter_temp}" ]; then
|
||||||
|
echo "adapter_temp.warning $max_adapter_temp"
|
||||||
|
fi
|
||||||
|
|
||||||
|
echo "multigraph arcconf_${adapter_id}_disks_temp"
|
||||||
|
echo "graph_title arcconf_${adapter_id} - Temperature of disks on adapter"
|
||||||
|
echo "graph_info arcconf_${adapter_id} - Temperature of disks on adapter $adaptername"
|
||||||
|
echo "graph_args -Y -A -l 0"
|
||||||
|
echo "graph_category disk"
|
||||||
|
echo "graph_vlabel C"
|
||||||
|
for disk in $disks; do
|
||||||
|
echo "temp_disk_$disk.label Temperature of disk $disk"
|
||||||
|
echo "temp_disk_$disk.info Temperature of disk $disk"
|
||||||
|
echo "temp_disk_$disk.min 0"
|
||||||
|
done
|
||||||
|
|
||||||
|
echo "multigraph arcconf_${adapter_id}_disks_usage"
|
||||||
|
echo "graph_title arcconf_${adapter_id} - Remaining usage of disks"
|
||||||
|
echo "graph_info arcconf_${adapter_id} - Remaining usage of disks in percent on adapter $adaptername"
|
||||||
|
echo "graph_args -u 100 -l 0"
|
||||||
|
echo "graph_category disk"
|
||||||
|
echo "graph_vlabel %"
|
||||||
|
for disk in $disks; do
|
||||||
|
echo "remaining_usage_disk_$disk.label Remaining usage on disk $disk"
|
||||||
|
echo "remaining_usage_disk_$disk.info Remaining usage on disk $disk"
|
||||||
|
echo "remaining_usage_disk_$disk.min 0"
|
||||||
|
echo "remaining_usage_disk_$disk.warning 80:"
|
||||||
|
done
|
||||||
|
|
||||||
|
for disk in $disks; do
|
||||||
|
echo "multigraph arcconf_${adapter_id}_disk_${disk}"
|
||||||
|
echo "graph_title arcconf_${adapter_id} - Disk $disk"
|
||||||
|
echo "graph_info arcconf_${adapter_id} - Error counters of disk $disk on adapter $adaptername"
|
||||||
|
echo "graph_args -Y -A -l 0"
|
||||||
|
echo "graph_category disk"
|
||||||
|
echo "graph_vlabel Errors"
|
||||||
|
error_counters=$(echo "$ARCCONF" | sed -n "/Device #$disk/,/Device #/ p" | grep -Pzo 'Aborted(.|\n)*Scsi Bus Faults.*[0-9]{1,6}' | tr '\0' '\n')
|
||||||
|
echo "$error_counters" | while read -r error_counter; do
|
||||||
|
name=$(echo "$error_counter" | sed -n 's/\([[:alpha:] ]*\).*/\1/p' | sed 's/ *$//g')
|
||||||
|
if [ -n "$name" ]; then
|
||||||
|
name=$(clean_fieldname "$name")
|
||||||
|
key="${name}_${disk}"
|
||||||
|
echo "$key.label $name" && echo "$key.info $name" && echo "$key.min 0"
|
||||||
|
# Sparse disks are "not ready", so don't warn
|
||||||
|
echo "$name" | grep -q "Not_Ready_Error" || echo "$key.critical 1"
|
||||||
|
fi
|
||||||
|
done
|
||||||
|
done
|
||||||
|
|
||||||
|
for disk in $disks; do
|
||||||
|
echo "multigraph arcconf_${adapter_id}_smartstats_${disk}"
|
||||||
|
echo "graph_title arcconf_${adapter_id} - S.M.A.R.T values disk $disk"
|
||||||
|
echo "graph_vlabel Attribute S.M.A.R.T value"
|
||||||
|
echo "graph_args -u 100 -l 0"
|
||||||
|
echo "graph_category disk"
|
||||||
|
echo "graph_info This graph shows the value of all S.M.A.R.T attributes of disk $disk."
|
||||||
|
smartstats=$(echo "$ARCCONF_SMARTSTATS" | sed -n "/\<PhysicalDriveSmartStats channel=\"[[:digit:]]\" id=\"$disk\"/,/\/PhysicalDriveSmartStats\>/ p")
|
||||||
|
echo "$smartstats" | while read -r attribute; do
|
||||||
|
name=$(echo "$attribute" | sed -n 's/.*name="\([[:alnum:] ()-/]*\)\".*/\1/p')
|
||||||
|
if [ -n "$name" ]; then
|
||||||
|
name=$(clean_fieldname "$name")
|
||||||
|
key="${name}_${disk}"
|
||||||
|
echo "$key.label $name" && echo "$key.info $name" && echo "$key.min 0"
|
||||||
|
threshold=$(echo "$attribute" | sed -n 's/.*thresholdValue="\([[:digit:]]*\).*/\1/p')
|
||||||
|
[ "$threshold" ] && echo "$key.critical $threshold:"
|
||||||
|
fi
|
||||||
|
done
|
||||||
|
done
|
||||||
|
|
||||||
|
exit 0
|
||||||
|
|
||||||
|
;;
|
||||||
|
|
||||||
|
esac
|
||||||
|
|
||||||
|
echo "multigraph arcconf_${adapter_id}_logicaldisks"
|
||||||
|
for logicaldisk in $logicaldisks; do
|
||||||
|
status=$(echo "$ARCCONF" | sed -n "/Logical Device number $logicaldisk/,/Parity Initialization Status/ p" | grep 'Status of Logical Device' | grep -c 'Optimal')
|
||||||
|
[ "$status" ] || status="U"
|
||||||
|
echo "status_logicaldisk_$logicaldisk.value $status"
|
||||||
|
done
|
||||||
|
|
||||||
|
echo "multigraph arcconf_${adapter_id}_online_disks"
|
||||||
|
online_disks=$(echo "$ARCCONF" | grep -cE 'State.*: Online')
|
||||||
|
[ "$online_disks" ] || online_disks="U"
|
||||||
|
echo "online_disks.value $online_disks"
|
||||||
|
|
||||||
|
echo "multigraph arcconf_${adapter_id}_temp"
|
||||||
|
adapter_temp=$(echo "$ARCCONF" | grep -oE "Temperature[\ ]+:\ [0-9]{1,3} C\/" | grep -oE '[0-9]+')
|
||||||
|
[ "$adapter_temp" ] || adapter_temp="U"
|
||||||
|
echo "adapter_temp.value $adapter_temp"
|
||||||
|
|
||||||
|
echo "multigraph arcconf_${adapter_id}_disks_temp"
|
||||||
|
for disk in $disks; do
|
||||||
|
disk_temp=$(echo "$ARCCONF" | sed -n "/Device #$disk/,/Device #/ p" | grep 'Current Temperature' | grep -oE '[0-9]+')
|
||||||
|
[ "$disk_temp" ] || disk_temp="U"
|
||||||
|
echo "temp_disk_$disk.value $disk_temp"
|
||||||
|
done
|
||||||
|
|
||||||
|
echo "multigraph arcconf_${adapter_id}_disks_usage"
|
||||||
|
for disk in $disks; do
|
||||||
|
usage=$(echo "$ARCCONF" | sed -n "/Device #$disk/,/Device #/ p" | grep 'Usage Remaining' | grep -oE '[0-9]+')
|
||||||
|
[ "$usage" ] || usage="U"
|
||||||
|
echo "remaining_usage_disk_$disk.value $usage"
|
||||||
|
done
|
||||||
|
|
||||||
|
for disk in $disks; do
|
||||||
|
echo "multigraph arcconf_${adapter_id}_disk_${disk}"
|
||||||
|
error_counters=$(echo "$ARCCONF" | sed -n "/Device #$disk/,/Device #/ p" | grep -Pzo 'Aborted(.|\n)*Scsi Bus Faults.*[0-9]{1,6}' | tr '\0' '\n')
|
||||||
|
echo "$error_counters" | while read -r error_counter; do
|
||||||
|
name=$(echo "$error_counter" | sed -n 's/\([[:alpha:] ]*\).*/\1/p' | sed 's/ *$//g')
|
||||||
|
if [ -n "$name" ]; then
|
||||||
|
name=$(clean_fieldname "$name")
|
||||||
|
key="${name}_${disk}"
|
||||||
|
value=$(echo "$error_counter" | grep -oE '[0-9]+')
|
||||||
|
[ "$value" ] || value="U"
|
||||||
|
echo "$key.value $value"
|
||||||
|
fi
|
||||||
|
done
|
||||||
|
done
|
||||||
|
|
||||||
|
for disk in $disks; do
|
||||||
|
echo "multigraph arcconf_${adapter_id}_smartstats_${disk}"
|
||||||
|
smartstats=$(echo "$ARCCONF_SMARTSTATS" | sed -n "/\<PhysicalDriveSmartStats channel=\"[[:digit:]]\" id=\"$disk\"/,/\/PhysicalDriveSmartStats\>/ p")
|
||||||
|
echo "$smartstats" | while read -r attribute; do
|
||||||
|
name=$(echo "$attribute" | sed -n 's/.*name="\([[:alnum:] ()-/]*\)\".*/\1/p')
|
||||||
|
if [ -n "$name" ]; then
|
||||||
|
name=$(clean_fieldname "$name")
|
||||||
|
key="${name}_${disk}"
|
||||||
|
value=$(echo "$attribute" | sed -n 's/.*normalizedCurrent="\([[:digit:]]*\).*/\1/p')
|
||||||
|
[ "$value" ] || value="U"
|
||||||
|
echo "$key.value $value"
|
||||||
|
fi
|
||||||
|
done
|
||||||
|
done
|
||||||
|
|
Loading…
Add table
Add a link