@ -0,0 +1,33 @@
|
|||
#!/bin/bash
|
||||
|
||||
# written by lars falk-petersen, dev@falk-petersen.no
|
||||
# clewarecontrol device serial must be set in config file:
|
||||
#
|
||||
# #munin/plugin-conf.d/cleware
|
||||
# [cleware]
|
||||
# #device serial. find it by running: clewarecontrol -l
|
||||
# env.serial 7778
|
||||
|
||||
case $1 in
|
||||
config)
|
||||
cat <<'EOM'
|
||||
graph_title Temperature And Humidity
|
||||
graph_vlabel C / %
|
||||
graph_category sensors
|
||||
temp.label Temperature
|
||||
hum.label Humidity
|
||||
graph_order temp hum
|
||||
graph_args --base 1000
|
||||
|
||||
EOM
|
||||
exit 0;;
|
||||
esac
|
||||
|
||||
clewarecontrol -ag > /dev/null 2>&1
|
||||
|
||||
echo -n "temp.value "
|
||||
clewarecontrol -d $serial -b -rt
|
||||
|
||||
echo -n "hum.value "
|
||||
clewarecontrol -d $serial -b -rh
|
||||
|